SupaRule Systems Ltd. of Limerick, Ireland produce a range of Ultrasonic cable height distance measuring units and Electro Magnetic Field (EMF) current detectors.
Cable height meters are used
to check clearances of overhead conductors at mid-span, to ensure a
safe height above people, vegetation and buildings. When an electricity
conductor carries more load (such as peak loads and seasonal
[air-conditioning/heating] loads), then the conductor heats up from the
extra current carried. This heating causes the strands and wires in the
aluminium, copper or steel conductor to expand. As the length expands
between its two fixed support points, then the droop or sag increases.
If
the sag increases too much, and the air temperature is too high, (the
air cools the metal), the conductors could reach ground level and cause
fires, bushfires or electrocution of bystanders. Usually, the
temperature increase is so high that the metal anneals or melts before
this can happen and electricity authorities do not allow the public to
be endagered or their equipment be ruined.
(This is why there are
bigger conductors, higher voltages and the need for more overhead
transmission lines into big cities. Underground conductors have to be
cooled by chemical means which makes them very expensive.)
Your
electricity authority is governed by regulations and standards which
stipulate these clearance heights and the easiest, quickest and safest
way to measure them is with a SUPARULE ultrasonic meter. The conductor
does not need to be LIVE.
Typical users of cable height meters are;
| 190 | 600 | 600E | 300D | 300Li | |
| Range @ dia.25mm | 3 to 15m | 3 to 15m | 3 to 23m | 3 to 15m | 3 to 15m |
| Range @ dia.12mm | 3 to 15m | 3 to 15m | 3 to 15m | 3 to 15m | 3 to 15m |
| Range @ dia. 5.5mm | 3 to 12m | 3 to 12m | ---- | 3 to 12m | 3 to 12m |
| Range @ dia. 2.5mm | 3 to 10m | 3 to 10m | ---- | 3 to 10m | 3 to 10m |
| Range @ dia. 1.5mm | ---- | ---- | ---- | ---- | 3 to 8m |
| Range with target | ---- | ---- | ---- | 1.5 to 45m | ---- |
| Auto Temp range | 0 to 35C | 0 to 35C | 0 to 35C | 0 to 35C | 0 to 35C |
| Operating temp | -10 to 45C | -10 to 45C | -10 to 45C | -10 to 45C | -10 to 45C |
| Number of cables | ONE | SIX | SIX | THREE | THREE |
| Calibrate feature | ---- | YES | YES | ---- | ---- |
| Manual & Auto temp | ---- | ---- | ---- | YES | ---- |

|
|
| 
Model 190 | 600 | 600E | 300D